Blog
Release date:Feb 12, 2026
Share:
For remote mining projects in the Arctic, Russian Far East, or other cold regions, the challenge is not just to “build a camp fast”, but to keep people safe, warm, and efficient through long winters at -40°C to -50°C. A cold‑resistant container house solution directly affects camp OPEX, staff retention, and HSE performance for mining owners and EPC contractors.
Below, the focus is on three questions mining clients care about most:
How to design cold‑resistant container houses: insulation, cold‑bridge control, anti‑freeze–thaw, anti‑condensation
What a real Russia -50°C container house project looks like
How to design the heating system and reduce energy consumption over the whole lifecycle

On mining sites in the Arctic, Russian Far East, and Central Asia, container houses are becoming the first choice for camps for several reasons.
Short construction window, fast deployment: Standard modules are prefabricated in the factory and only need lifting and simple installation on site, which is critical in areas where you only have a few workable months per year.
Customisable performance: By upgrading insulation, doors and windows, and key structural details, the same container house platform can be turned into a cold‑resistant mining camp unit rated down to -50°C.
Predictable lifecycle cost: A higher insulation level at the beginning can significantly cut long‑term heating and maintenance costs, which is especially important for multi‑year mining operations.
For mining procurement and technical teams, the key is not “buying boxes”, but “buying a complete camp system optimised for extreme cold”.

For cold regions and Arctic mining camps, container house walls, roofs, and floors need enhanced, layered insulation.
Walls and roof: A common build‑up is outer steel sheet + steel frame + high‑density insulation (such as rock wool or PU) + inner panel, designed to meet strict U‑value targets for cold regions.
Floor: Extra insulation and, where needed, an elevated floor help reduce contact with frozen ground and limit heat loss and condensation at the floor level.
For mines aiming to push down energy bills further, high‑performance windows (double or triple glazing, thermally broken frames) are a must to eliminate weak points in the envelope.
In Russia and other severe cold mining projects, cold bridges are a major cause of condensation, mould, and unwanted heat loss.
Typical cold‑bridge locations include:
Connections between columns, beams, wall studs and outer panels
Slab–wall joints
Window and door frame junctions
Parapets and eaves at roof level
Effective engineering measures:
Minimise continuous metal paths from inside to outside, or wrap them with continuous external insulation
Add insulation all around window and door frames to avoid exposed metal frames
Use thermal simulations for key nodes and refine the detail until surface temperatures stay above dew point
In a two‑storey container house project in Khabarovsk, Russia, optimised cold‑bridge details significantly improved comfort and energy performance under extreme winter conditions, with positive long‑term feedback from the client.
Cold regions are not only about low temperatures; repeated freeze–thaw cycles can damage foundations and cladding if not considered properly.
Common engineering strategies:
Foundations: Choose independent or strip foundations according to frost depth and soil type, and reduce direct impact of frost heave on the structure.
Drainage: Design the camp platform and surroundings with organised drainage so that meltwater does not stay around foundations.
Exterior finishes: Use cladding and roofing materials with good freeze–thaw resistance, easy maintenance, and low risk of cracking and leakage.
For long‑term mining camps, freeze–thaw durability should be part of material and detail selection from day one, not treated as a temporary construction camp.
With -30°C outside and about 20°C inside, the risk of condensation is very high if details are not handled correctly.
Key control points:
Airtightness: Improved sealing for doors, windows, and joints reduces moist indoor air migration into cold parts of the wall.
Proper insulation and vapour‑barrier layout: Insulation usually sits towards the cold side, with a continuous vapour barrier on the warm side to prevent moist air reaching cold layers.
Ventilation: Mechanical exhaust in bathrooms, kitchens, and laundry rooms keeps indoor humidity under control.
With these measures, container houses can maintain dry wall assemblies and surfaces even under long heating seasons and sharp temperature drops.
In a container house project in Russia’s Far East, local minimum temperatures can reach -50°C, imposing very high requirements on camp structure and insulation.

Location: Cold regions such as Khabarovsk, with long winters and extremely low temperatures.
Function: Two‑storey container houses for office and accommodation, designed for continuous multi‑year operation.
Client priorities: Thermal performance, cold‑bridge control, installation speed, and long‑term maintenance cost.
During early design, the team analysed local climate data, wind and snow loads, and permafrost conditions to define structural and insulation levels.
The project adopted several deep optimisations:
Enhanced envelope: Walls and roof used thicker, higher‑grade insulation systems to meet transmission requirements for cold regions.
Cold‑bridge control: Box‑to‑box joints, slab edges, and other critical spots were re‑designed with thermal breaks, added insulation blocks, and cover plates.
High‑performance openings: High‑insulation windows and optimised frame joints reduced temperature gradients around openings.
Considering the harsh winter construction environment and limited on‑site time, the camp relied heavily on factory‑prefabricated container house modules, minimising on‑site welding and complex work, which improved both safety and installation speed.
After completion, the houses have gone through multiple winters in local conditions, with the owner giving positive feedback on thermal comfort, structural performance, and living quality.
For mining buyers, such -50°C container house references are a strong indicator of a supplier’s capability in extreme cold:
Real projects in similar temperature zones
Dedicated design packages for insulation, cold bridges, and structure
Long‑term operation data and owner references
For cold‑region and Arctic mining camps, the heating system is usually the biggest energy consumer in the camp. Choosing the right system and matching it with a high‑performance container house shell is the only way to balance CAPEX and OPEX.
Different mine sizes, fuel prices, and project durations lead to different optimal heating solutions.
Typical options:
Central boiler + hydronic heating (radiators or floor heating): Fits mid‑ to large‑scale, long‑term mining camps and enables centralised management.
Room‑level electric heating: Simple for small or short‑term camps where electricity cost is acceptable.
Air‑source heat pumps: Can bring higher efficiency in suitable climates, but need careful selection and anti‑freeze design in very low temperature regions.
No matter which system is chosen, a well‑insulated, low‑bridge container house envelope is the base; otherwise you are “heating the outside air”.
Many energy problems are locked in during design, not operation. Mining clients and EPCs can focus on:
U‑value targets: Define required U‑values for walls, roof, floor, and windows to guide material choice and thickness.
Window‑to‑wall ratio: Keep enough daylight while avoiding excessive glazing that drives up heat loss.
Functional zoning: Place high‑heat‑load rooms more centrally or on the upwind side to reduce exposure and heat loss.
Some projects also run energy simulations to compare different envelope configurations and heating concepts, helping owners choose the best balance between initial investment and long‑term energy cost.
Even with a well‑designed camp, there is room to improve performance during operation:
Zonal control: Use valves and thermostats to set different temperatures for each area based on occupancy, avoiding heating empty spaces.
Regular checks: Inspect insulation and window seals, and repair damage or ageing seals quickly to avoid continuous energy loss.
Staff training: Simple rules for window opening, door usage, and thermostat settings can deliver noticeable savings over a multi‑year mining project.
Scan the QR code to follow